  NEHA MIRACLE IRON REMOVER AND WATER PURIFIER - TEST RESULTS
     

 Before installing the filter After installing the filter 
     
  Test Unit Value   Test Unit Value  
                 
  pH   5.8   pH   7.8  
  Electrical Conductivity µs/cm 612   Electrical Conductivity µs/cm 361  
  Total Solids mg/l 137   Total Solids mg/l 255  
  Total Hardness mg/l 135   Total Hardness mg/l 130.4  
  Nitrate Nitrogen as N mg/l 0.001   Nitrate Nitrogen as N mg/l 0.005  
  Nitrite Nitrogen as N mg/l 0.05   Nitrite  Nitrogen as N mg/l -  
  Chloride mg/l 50   Chloride mg/l 32.6  
  Total Iron mg/l 5.6   Total Iron mg/l 0.11  